Do not dilute with any other solvents. Use as-is. For best results apply with a Presolve system from dome lids and cleanout or vent caps, without entering the tank. Recirculate with a pump system. For best results, seal up the tank and allow it to stand for 30 minutes after application. Especially effective for latex removal from Road Tankers & ISO containers with polymerized film in vapor space. Apply while the tank is still hot from the wash and allow to stand for 30 minutes. LIQUI-FIRE RXE is a stellar performer for removing 4-ADPA. Special SOP available upon request for the removal of this material.
Appearance…………………….. Clear, Colorless Liquid
Odor………………………………. Napthenic
pH………………………………….. N/A
Specific Gravity……………….. 0.97
Percent Active………………… 100%
Flash Point……………………… 138° F
Dilution………………………….. None – Use undiluted*
Foam……………………………… N/A
Hardwater Tolerance……… N/A
Chlorinated Solvents…….. None
Ammonia…………………….. None
Phosphate…………………….. None
Storage Stability……………… Excellent(emulsifiable)
* 1 yr under normal conditions
Vapors can cause nausea, dizziness, nausea, stupor, vomiting, headache, and/or irritation to nose, throat, and respiratory system. Irritating to eyes and skin. Causes irritation to eyes. Prolonged exposure may irritate skin.